Corrosion from chlorine contamination of test solution




2004

Does anyone have any knowledge of chlorine contamination of parts from copper sulphate [on eBay or Amazon]testing?

We are currently trying to prove out a passivation line. We experienced corroded parts as a result of chlorine deposits.

All solutions were checked for chlorine content. The only solution that had a positive result was our copper sulphate solution mixed per ASTM A967. Any help would be appreciated.

Shawn Struzik
endoscopy - Orchard Park, New York



No chlorides in the copper sulphate test solution unless you used bad water. This is not the copper sulphate that is causing this if you are gettin chloride contamination.

lee kremer
lee kremer sig
Lee Kremer
Stellar Solutions, Inc.
supporting advertiser
McHenry, Illinois
stellar solutions banner
2004




(No "dead threads" here! If this page isn't currently on the Hotline your Q, A, or Comment will restore it)

Q, A, or Comment on THIS thread -or- Start a NEW Thread

Disclaimer: It's not possible to fully diagnose a finishing problem or the hazards of an operation via these pages. All information presented is for general reference and does not represent a professional opinion nor the policy of an author's employer. The internet is largely anonymous & unvetted; some names may be fictitious and some recommendations might be harmful.

If you are seeking a product or service related to metal finishing, please check these Directories:

 
Jobshops
Capital
Equipment
Chemicals &
Consumables
Consult'g, Train'g
& Software


About/Contact  -  Privacy Policy  -  ©1995-2024 finishing.com, Pine Beach, New Jersey, USA  -  about "affil links"