2003
I am running a bench reaction in which I am using a steel temp. probe to monitor my reaction temp. One of the raw materials I am using is Hydrochloric acid. I ended up with a green layer on my temp. probe which in turn discolored my batch. Is the acid eating up my steel?
Thanks.,
Lina Nasr
Champion Technologies - Houston, Texas
2003
Yes it is.
Trevor Crichton
R&D practical scientist
Chesham, Bucks, UK
finishing.com is made possible by ...
this text gets replaced with bannerText
Disclaimer: It's not possible to fully diagnose a finishing problem or the hazards of an operation via these pages. All information presented is for general reference and does not represent a professional opinion nor the policy of an author's employer. The internet is largely anonymous & unvetted; some names may be fictitious and some recommendations might be harmful.