-----CHEM FILM ANALYSIS TESTING
I AM INTERESTED IN SETTING UP IN HOUSE TESTING FOR OUR CHEM FILM PROCESS TO MIL-C-5541. WHAT DO I NEED AND IS THERE A MACHINE THAT WILL DO THE TESTING AUTOMATICALLY.
DAN KAISER- HICKSVILLE, New York
2003
2003
Solution Analysis including Cleaning Solutions - Weekly
Salt Spray Testing per ASTM ASTM B117 - Monthly 5 panels 0.020 x 3 x 10" at 6 Degrees for 168 Hours
Adhesion (if applicable) - Monthly
Visual - Every Lot
Nothing here is automatic, and you need to look after/document the salt spray unit twice a day.
Fred Mueller- Southampton, Pennsylvania, USA
Sorry! Finishing.com is temporarily Read-Only.
Ted Mooney is retiring but I have several offers to take it over.
We're working hard to make sure we find it the best new home.