topic 8251

Electroless Nickel Plating Integrity


2001

Our product is made out of brass with an electroless nickel plating finish as means of corrosion resistance. The product is exposed to chlorinated water and lime and other chemicals to kill bacteria. The problem we are experiencing is that it appears that the water is attacking the surface finish and also the Buna N o-rings that are in the product. Is this possible.

Bob Ansary
- Clifton, New Jersey

none
adv.
this text gets replaced with bannerText
spacer gets replaced with bannerImages

Q, A, or Comment on THIS thread SEARCH for Threads about ... My Topic Not Found: Start NEW Thread

Disclaimer: It's not possible to diagnose a finishing problem or the hazards of an operation via these pages. All information presented is for general reference and does not represent a professional opinion nor the policy of an author's employer. The internet is largely anonymous & unvetted; some names may be fictitious and some recommendations may be deliberately harmful.