Summary for nsf test for galvanizing Discussion
NSF test for galvanized pipe is the focus of this thread. Mustafa Sag says his hot-dip galvanizing samples were sent to NSF but did not pass, and he asks how to make them pass. In reply, the answerer first clarifies that the issue is likely NSF 61, the drinking-water health-effects standard, and asks what part of the test failed, suggesting lead as a possible cause. The answer also notes that lead-free galvanizing is possible, implying that reducing or eliminating lead in the process may help meet the requirement. Because the thread excerpt is brief, no final fix is given; the key advice is to identify the exact failure mode from NSF and then adjust the galvanizing chemistry accordingly, especially if lead content is the problem.
January 2, 2014
Q. Hi Everyone ;
My process is hot dipping galvanizing. We have sent the samples of pipe to the NSF, but we couldn’t pass the NSF test.
How can I pass the test? Please help me.
Mustafa SAG
– TURKEY
A. Hi Mustava.
I assume you are referring to NSF 61, “Drinking Water System Components – Health Effects” certification? Did they tell you in what way you did not pass the test?
Possibly lead? It is possible to do lead-free galvanizing, if so.
Regards,

Ted Mooney, P.E.
Striving to live Aloha
finishing.com – Pine Beach, New Jersey
Need quick confidential answers? $25
Need project assistance? $100/hr.
January 2014