ER2209 vs. ER309 Corrosion Resistance Comparison



August 14, 2012

Q. Our company is having (4) oilfield produced water (briny) tanks fabricated with 2304 Duplex stainless steel. The tank welds will be made with ER2209 electrodes. However, the appurtenances are 316L and will be welded with the ER309 electrode which is acceptable. My question is would it be advisable to cap the internal welds (wettable surfaces) with the ER2209 electrode for added corrosion protection? This is our first experience with Duplex steel for tank fabrication.
Thanks.

Dave Griffin
QA - McKittrick, California


none
finishing.com is made possible by ...
this text gets replaced with bannerText
spacer gets replaced with bannerImages

Q, A, or Comment on THIS thread -or- Start a NEW Thread

Disclaimer: It's not possible to fully diagnose a finishing problem or the hazards of an operation via these pages. All information presented is for general reference and does not represent a professional opinion nor the policy of an author's employer. The internet is largely anonymous & unvetted; some names may be fictitious and some recommendations might be harmful.