CCT-1 test for stainless steel SS-302 after passivation
WHAT IS THE BEST METHOD FOR PASSIVATION OF STAINLESS STEEL BOLT (MATERIAL SS-302), TO WITHSTAND 100 CYCLES OF CCT-1 TEST
SURINDER ARYAINDUSTRY - Rohtak, Haryana, INDIA
March 18, 2009
Passivate per ASTM A967 specification. If you are passivating correctly, the next major factor in corrosion test endurance is the grade of stainless you are using. I.e. 316 is better than 304, etc.
Let us know if we can help you.
Ray Kremer
Stellar Solutions, Inc.
McHenry, Illinois
April 15, 2009