| Search our quarter-million Q&As |
Home of the finishing HOTLINE since 1989
-----Sludge in phosphating line (difference between of galvanized sheet and normal sheet)
March 4, 2008
Dear sir or madam,
I want to compare sludge and waste in phosphate tank. when we use galvanize sheet and normal sheet in phoshating line before painting in automotive line .
In Some text says:
1- Sludge for normal sheet 5-10 mg/Lit
2- Sludge for galvanized sheet 0.5mg/Lit
3- Sludge for aluminium 10-30 mg/Lit
Could you please guide me this number is routine and usual or not?
Best regards
- Tehran, Iran
Can you please put this in context, Nader, because we don't know where you're going. Do you already phosphatize galvanized steel but not plain steel? Or is it vice versa? Or you are just planning to build a line? Or you already phosphatize and your numbers disagree with the literature? Thanks.

Ted Mooney, P.E.
Striving to live Aloha
finishing.com - Pine Beach, New Jersey
Need quick confidential answers? $25
Need project assistance? $100/hr.
March 4, 2008
Sorry! Finishing.com is temporarily Read-Only.
Ted Mooney is retiring but I have several offers to take it over.
We're working hard to make sure we find it the best new home.