-----What is E512 per MIL-F-14072
Q. What is E512 per MIL-DTL-14072 [⇦ this spec on DLA]?
Larry Davilaqa manager - Gardena, California
2007
Aluminum How-To
"Chromating - Anodizing - Hardcoating"
by Robert Probert
You'll love this book. Finishing.com has sold a thousand copies without a return request 🙂
A. See MIL-DTL-14072E Finishes for Ground Based Electronic Equipment, page 44:
TABLE IV. Finishes or processes other than painting or plating (E) - continued.
For Use On: Aluminum alloys when Low Resistance Electrical Contacts are required; service temperatures not to exceed 60 °C
Type Exposure: II
Finish Number: E512
Finish Process: 1) Preconditioning not required.
2) Passivate with chemical film per MIL-DTL-5541
[⇦ this spec on DLA], Class 3.
- Goleta, California
Rest in peace, Ken. Thank you for your hard work which the finishing world, and we at finishing.com, continue to benefit from.