| Search our quarter-million Q&As |
Home of the finishing HOTLINE since 1989
-----Anodized 6061-T6 galvanic differential
What effect will applying a hardcoat anodized finish as per MIL-A-8625 / MIL-PRF-8625 [⇦ this spec on DLA], type III, class 2 have on the galvanic differential of 6061-T6 Aluminium?
Nicol McNeill- Glasgow, Scotland
2000
Hello, Nicol. Anodizing converts aluminum to non-conductive aluminum oxide and aluminum hydroxide. So the coating itself is an insulator which will not corrode; and the aluminum underneath it is protected from galvanic corrosion as long as the coating is not penetrated.

Ted Mooney, P.E.
Striving to live Aloha
finishing.com - Pine Beach, New Jersey
Need quick confidential answers? $25
Need project assistance? $100/hr.
April , 2007
Sorry! Finishing.com is temporarily Read-Only.
Ted Mooney is retiring but I have several offers to take it over.
We're working hard to make sure we find it the best new home.