Letter 4036
Conductive finish for colled rolled
steel
-
I am looking for a finish I can apply to colled rolled steel that
is conductive. I have EMI issues on a product and and am currenly
using clear zinc on my CRS chassis, but the coating is not conductive
enough. Anys suggestions? Someone suggested "alkaline zinc", but am
not familiar with it.
David Rapp
medical - sunnyvale, ca
-
Zinc can be electroplated from an acid bath, a cyanide bath, or an
alkaline non-cyanide bath. "Someone" was suggesting a bath you could
use, and perhaps describing the relative advantages of it, but I am
not aware of any significant difference in conductivity of the plated
surface that might result from using one zinc bath versus another.
The clear chromate you are using will give you a lower contact
resistance than would a yellow chromate.
Please also see letters #485,
#2287, and
#3617.
|
|

Ted Mooney, P.E.
finishing.com
Brick, New Jersey
|
-
-
 |