Adhesion problem of plated gold
++++
After deposition (thermal evaporation) of 2500A chrome + gold , we are plating it to 4 micron thickness using gold potassium cynide salt in an electrolytic cell with a pulsed supply. The problem is that the gold when it reaches 4 micron thicness does not adhere well with the sapphire substrate. Any suggestions for improving the adhesion.
Vanya SrivastavSSPL, Semiconductors - Delhi, India
++++
What are your plating and pretreatment processes? No-one can advise you if they don't know what you are doing.
|
Trevor Crichton R&D practical scientist The Pheasantries - Chesham, U.K. |