![]() (Cycles thru suppliers) |
|
![]() |
Letter 3571 Passivation problems with T304 stainless steel- We have been passivating Type 304 stainless steel according to ASTM standards and have questionable results. We have our vendor degrease the parts and then wash them in an alkaline bath for 10 minutes. After 10 minutes the parts are rinsed in clean water before being immersed in a Nitric 2 solution. 20 to 45 volume percent of nitric acid. The parts are then immersed for 30 minutes at a temperature range of 70 to 90 degrees F. They are then rinsed in water left to air dry. after they are dry they are then tested with a solution of potassium ferricyanite nitric acid and they still appear to be contaminated with free iron. Does anyone else experience these same problems? Mark Early
First of two simultaneous responses-- - Your test is the Ferroxyl Test and is very sensitive. I doubt if you will have many parts pass it with your standard cycle. A much longer caustic clean followed by a much much longer passivation step will help. You will have to be exceptionally careful that any machine that these parts are worked on are surgically clean to avoid iron particles being forced into the surface. My bet is you will end up electropolishing them to pass this test. It is hard to pass with 316, let alone 304. (If you are honest) James Watts - FL
Second of two simultaneous responses-- 1 October 1999 Hi Mark , Best regards
- Mark: I agree with all those who recommended electropolishing. Look up Metal Coating Process Corporation in the Suppliers' Directory on this web site. There is a link that will take you to our own site where you will find background information on the process. Regards, Ed Bayha
++ Maybe you're water is not démineralised or you wait too much time with the ferroxyl test on. After a minute it is normal that the test turn blue cause of the air. Jean Lambert
Dear Reader: please choose what you want to do.
![]() |
|
Save
This Page (why?) - Home - ©1995-2008 finishing.com