Letter 33096 Adhesion problem of plated gold [India]++++ After deposition (thermal evaporation) of 2500A chrome + gold , we are plating it to 4 micron thickness using gold potassium cynide salt in an electrolytic cell with a pulsed supply. The problem is that the gold when it reaches 4 micron thicness does not adhere well with the sapphire substrate. Any suggestions for improving the adhesion. Vanya Srivastav
++++ What are your plating and pretreatment processes? No-one can advise you if they don't know what you are doing.
Dear Reader: please choose what you want to do--
![]() |
|
Save