Letter 33096
Adhesion problem of plated gold
++++
After deposition (thermal evaporation) of 2500A chrome + gold , we
are plating it to 4 micron thickness using gold potassium cynide salt
in an electrolytic cell with a pulsed supply. The problem is that the
gold when it reaches 4 micron thicness does not adhere well with the
sapphire substrate. Any suggestions for improving the adhesion.
Vanya Srivastav
SSPL, Semiconductors - Delhi, India
++++
What are your plating and pretreatment processes? No-one can
advise you if they don't know what you are doing.
|
|
Trevor Crichton
R&D practical scientist - UK
|
Dear Reader, please --
- Answer or follow-up on this subject (in non-commercial
fashion).
-
- My company is a supporting advertiser at
finishing.com and we want the contact information to reach
the inquirer privately.
-
- Post a new
question or inquiry on a different subject.
-
 |