Letter 25037 Non wet on QFP package during reflow [Malaysia]+++ I have a customer complaining of random leads on a QFP package not reflowing during their reflow process. Pictures shows that there was sufficient solder paste on the PCB pad and there was no coplanarity issues. They reported a high fallout (as high as 30% on certain batches of material). Among actions taken so far are changing the solder paste which have reduced the fallout to 0.5% However there have been spikes off and on and customer are demanding for 0% fallout. I am currently trying to simulate the problem using Ceramic Reflow Test Method, stated in the J-STD-002B. The spec. states that parts needs to be preconditioned (steam aged ) for 8 hrs on tin lead finishing products. However all my parts have failed this test. I am currently using ROL0 class type paste but the spec recommends using a ROL1 class paste. I will be testing this soon. My questions are : 1. Is anyone familiar with ceramic plate test method? Any help right now would be great. Thanks, Vickneswaran